MILWAUKEE - MC811 MAX MONITOR pH/EC/TEMP. 24/24h.
The MC811 MAX monitor automatically monitors and displays pH/EC/Temp levels. Just calibrate the parameters and let the Milwaukee MAX monitor do the rest. The Milwaukee MC811 MAX pH/EC/Temp Monitor...
The MC811 MAX monitor automatically monitors and displays pH/EC/Temp levels. Just calibrate the parameters and let the Milwaukee MAX monitor do the rest.
The Milwaukee MC811 MAX pH/EC/Temp Monitor is the tool of choice for people who want to know 24/7 what their pH and nutrient levels are on an ongoing basis. Common uses are nutrient tanks, hydroponics and aquariums.
The Milwaukee MC811 pH/EC/Temp Monitor offers:
The Milwaukee MAX Monitor offers an accuracy of 0.2 pH with manual two-point calibration, EC accuracy of ± 2% full scale and temperature accuracy of ± 0.5 °F (0.3 °C).
AUTOMATION
Simply calibrate the parameters and start monitoring 24/7!
EASY INSTALLATION
The MC811 MAX pH/EC/Temp monitor comes with a complete mounting kit that includes a probe holder.
Features Milwaukee MC811:
- Easy to read current results quickly with 3 large digital RETRO-ILLUMINATED LCD readouts.
- Accurate to ±0.2 pH (0.0 pH to 12.0 pH).
- Accurate ±2% EC full scale.
- External switch above the unit converts EC conductivity to EC using a conversion factor of 0.5 or 0.7.
- Simple two-point pH and one-point EC calibration for greater accuracy with manual trimmers for easy adjustment.
- MA911B/2 double junction laboratory pH electrode (included) filled with gel for low maintenance and high performance.
- Meter probe cables for greater flexibility during testing.
- 12 VDC power supply.
Storage:
The pH probe must be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Leaving the probe to dry out may also cause clogging of the junction hole.
Storage in pH probe storage solution or pH calibration buffers will help solve both of these problems. Do not store in tap water or deionised water. This will damage the sensitivity of the probe.
The best way to store the probe is with the probe cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also advisable to store the electrode upright to further reduce the risk of leakage.
Technical specifications MC811 Milwaukee:
- pH range: 0.0 - 12.0 pH
- pH resolution: 0.1 pH
- pH accuracy: ±0.2 pH
- pH calibration: Manual, 2 points (trimmer)
- pH Probe: MA911B/2 (included)
- EC Range: 0.00 - 5.00 mS/cm
- EC Resolution: 0.01 mS/cm
- EC accuracy: ±2% full scale
- EC calibration: manual, 1 point (trimmer)
- EC probe: MA812 (fixed, included)
- Temperature range: 14.0 to 140.0 °F (-10.0 to 60.0 °C)
- Temperature resolution: 0.1°F / 0.1°C
- Temperature accuracy: ±0.5°F / ±0.3°C
- Temperature calibration: factory calibrated
- Temperature compensation: automatic, 41 to 122°F (5 to 50°C), (TDS/EC readings only)
- Temperature probe: Stainless steel (fixed, included)
- Power supply: 12 VDC adapter (included)
- Dimensions: 6.3" x 4.3" x 1.4" (160 mm x 110 mm x 35 mm)
- Weight: 1.2 lbs. (560 g)
-
110x35x160 cm (WxLxH)
-