Available
MILWAUKEE - MW600 PRO DISSOLVED OXYGEN METER
Cod. MW600
Brand: MILWAUKEE INSTRUMENT
The MilwaukeeMW600 PRO portable dissolved oxygen meter is one of Milwaukee's most popular meters due to its reliable and fast operation as well as its accuracy. The Milwaukee PRO DO Meter is...
Standard price
€288,99 VAT included(22%)
The MilwaukeeMW600 PRO portable dissolved oxygen meter is one of Milwaukee's most popular meters due to its reliable and fast operation as well as its accuracy.
The Milwaukee PRO DO Meter is preferred by people looking for laboratory level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists to educators, fish farmers and koi pond owners.
Milwaukee MW600 PRO features:
- Fast and easy-to-read results with large digital LCD display
- Repeatable, accuracy up to ±1.5% FS
- Lightweight and portable
- Simple 2-point outdoor calibration
- Uses reinforced MA840 polarographic probe with an oxygen-permeable polytetrafluoroethylene (PTFE) membrane sensor
- 5 o-rings, membranes and a protective cap included
- 10-foot probe cable for greater flexibility during testing
- 70 hours of autonomy with continuous use (battery included) with low battery warning
OPEN AIR" CALIBRATION PROCEDURE.
1. Remove the membrane
Remove the membrane from the probe end and dry the diode.
2. Zeroing the display
Connect the probe to the base unit and switch on the unit. The display should read 0.0. If it does not, go to the "0" position of the screw on the front of the unit with the screwdriver provided and through the access hole have the unit's display read 0.0.
3. Fill the membrane
Go to the membrane and put the "O" ring inside the membrane on the shoulder at the base of the wires. Fill the membrane just before the O-ring with the MA9071 electrolyte solution. Make sure there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)
4. Attach the membrane
Screw the membrane onto the probe.
5. Allow to stabilise
Switch on the instrument and hang the probe on the end of a table facing downwards and let the unit's display stabilise (this may take 5 to 15 minutes)
6. Adjust
Push down and hold the 'Cal' button on the front of the instrument and use the screwdriver to go to the front Cal position '100%' and let the display show 100.
Technical Specifications MW600:
- O2 range: 0.0 to 19.9 mg/l
- O2 resolution: 0.1 mg/L
- O2 accuracy: ±1.5% full scale
- Calibration: Manual on 2 points (zero and slope)
- Temperature compensation: Automatic, 0 to 30°C
- Probe: MA840 rechargeable polarographic probe included
- Membranes: 5 included
- Environment: 0 to 50°C / 32 to 122°F; RH max. 95%.
- Battery type: 1 x 9 V alkaline (included)
- Battery life: approx. 70 hours of continuous use
- Dimensions: 5.7 x 3.1 x 1.6 inches
- Weight: 7.5 ounces with battery
-
0,15 kg
-
1
-
5999567670793
€ 185,89 VAT included(22%)